Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Analyst ; 149(4): 1081-1089, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38204338

RESUMO

Gastrointestinal bleeding (GIB) is a serious medical condition, which requires immediate attention to establish the cause of the bleeding. Here, we present the development of a miniaturised electrochemical impedance spectroscopy (EIS) device for the detection of GIB. The device performs EIS measurements up to 100 kHz. Following the development of an immunosensor for haemoglobin (Hb) on screen printed electrodes, the EIS device was used for detecting Hb as an early indication of bleeding. The sensor was able to detect Hb in a redox solution in a linear range between 5 µg mL-1 and 60 µg mL-1, with a limit of detection of 13.3 µg mL-1. It was also possible to detect Hb in simulated intestinal fluid, without the need for a redox solution, within a range of 10 µg mL-1 to 10 mg mL-1 with a limit of detection of 2.31 mg mL-1. The miniature EIS device developed in this work is inexpensive, with an estimated cost per unit of £30, and has shown a comparable performance to existing commercial tools, demonstrating its potential to be used in the future as an ingestible sensor to detect GIB. All these measurements were carried out in a purpose built flow cell with supporting hardware electronics outside the cell. Integration of the hardware and the sensing electrodes was demonstrated in pill form. This pill after integration sampling fluidics has potential to be used in detecting gastrointestinal bleeding.


Assuntos
Técnicas Biossensoriais , Hemoglobina Falciforme , Humanos , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Espectroscopia Dielétrica , Hemorragia Gastrointestinal/induzido quimicamente , Hemorragia Gastrointestinal/diagnóstico , Eletrodos , Limite de Detecção , Técnicas Eletroquímicas/métodos , Ouro/química
2.
Micromachines (Basel) ; 13(10)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36295963

RESUMO

A handheld USB-powered instrument developed for the electrochemical detection of nucleic acids and biomolecular interactions is presented. The proposed instrument is capable of scanning ± 2.25 V while measuring currents up to ±10 mA, with a minimum current resolution of 6.87 pA. Therefore, it is suitable for nucleic acid sensors, which have high background currents. A low-cost microcontroller with an on-chip 16-bit analog-to-digital converter, 12-bit digital-to-analog converter, and a built-in USB controller were used to miniaturize the system. The offset voltages and gain errors of the analog peripherals were calibrated to obtain a superior performance. Thus, a similar performance to those of the market-leader potentiostats was achieved, but at a fraction of their cost and size. The performance of the application of this proposed architecture was tested successfully and was found to be similar to a leading commercial device through a clinical application in the aspects of the detection of nucleic acids, such as calf thymus ssDNA and dsDNA, and their interactions with a protein (BSA) by using single-use graphite electrodes in combination with the differential pulse voltammetry technique.

3.
Anal Biochem ; 591: 113538, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31830435

RESUMO

The abnormal concentrations or absence of biomolecules (e.g., proteins) in blood can further be used in diagnosis of a particular pathology at an early stage. Current studies are intensely focusing on the analysis of interaction and detection of biomolecules via point-of-care systems (POCs), allowing miniaturized and parallelized reactions, simultaneously. Recent developments have shown that the collaboration of electrochemical sensing techniques and POCs to overcome challenging problems in health-care settings provides new approaches in diagnosis and treatment of diseases. The aim of this study was to adapt the alanine aminotransferase (ALT) enzyme to the platinum (Pt) thin film electrode system and quantitatively determine the enzyme levels via enzymatically generated H2O2 with differential pulse voltammetry (DPV). A simple potentiostat architecture with expanded sweep range utilizing dual LMP91000 devices was developed and adapted to the needs of the biosensor. In order to calibrate the system, known concentrations of H2O2 were also tested. Moreover, signals associated with the other electroactive species coming from the ALT reaction were eliminated. Resulted potential range has been achieved between +500 mV and +900 mV and the linear range was found to be 0.05 M-0.5 M for H2O2, whereas 5 UL-1 to 120 UL-1 for ALT enzyme.


Assuntos
Alanina Transaminase/análise , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Peróxido de Hidrogênio/análise , Animais , Eletrodos , Platina/química , Testes Imediatos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...